Welcome to the company website
hotline:+441315070216

Flexim FLUXUS G721 CA Compressed Air Flow Meter (Obsolete)

Release time:2025-10-15 10:50:31      publisher:小编  Page View:

flexim-g721-ca-1000x1000.jpg

Flexim FLUXUS G721 CA Compressed Air Flow Meter (Obsolete)

Product Description

This product is obsolete. Relevant documents and drawings are listed below. Please contact your local Emerson representative for your measurement needs.

Specifications

  • Fluid type
  • Air, nitrogen, oxygen, helium, argon
  • Accuracy
  • Measurement uncertainty of the measuring system (volumetric flow rate): ±0.3 % of reading ±0,005 m/s (±0.02 ft/s)
    Measurement uncertainty at the measuring point (volumetric flow rate): ±1…2 % of reading ±0,005 m/s (±0.02 ft/s)
  • Repeatability
  • 0.15 % of reading ±0,005 m/s (±0.02 ft/s)
  • Flow Channels
  • up to 2
  • Range
  • Flow Velocity Range: 0,01…35 m/s (0.03 to 115 ft/s), depending on pipe diameter
  • Certifications/Approvals
  • FM Class I /Div 2
    ATEX/IECEx Zone 2
    PESO
    KOSHA
  • Power supply
  • 100-230VAC
    24VDC
    12VDC
  • Pipe size
  • 10 to 250 mm (0.39 to 9.8 inch)
  • Pressure range
  • 1barg (15 psig) to unlimited
  • Temperature range (media)
  • -40 to +130°C (-40 to +266°F)
  • Output
  • 4-20mA active/passive
    4-20mA HART active/passive
    pulse/frequency/binary
    voltage
  • Input
  • Temperature
    4-20mA active/passive
    binary
    voltage
  • Communication Protocol
  • Modbus RTU/TCP
    BACnet MSTP/IP
    Profibus PA
    Foundation Fieldbus
  • System configuration and installation
  • For more detailed Information please download the Technical Specifications

Features

  • Non-intrusive compressed air and technical gas flow measurement from 3 bar absolute onwards.
  • Available as a dual channel meter, stainless steel housing, ATEX/IECEx and FM approval.
  • Integrated standard volume flow calculation.
  • Extreme measurement dynamics from lowest to highest flow velocities - easy detection of leakages and load peaks.
  • Bi-directional measurement, able to detect back-flow
  • Simple and cost-effective retrofitting without shut down.
  • USB and LAN interface.
  • Communication interfaces Modbus TCP, Modbus RTU, BACnet MS/TP, BACnet IP, M-Bus.
  • Advanced Meter Verification.


Previous article:No more
Next article:No more

CLASSIFICATION

  • Gas Analysers
  • Oxygen Probes
  • Moisture analyzer
  • Chromatographic analyzer
  • Tunnel sensor
  • Ultraviolet analyzer
  • Liquids Analysers
  • Steam Analysers
  • Compressed Air Analysers
  • Mass Flow Analysers
  • Thermal Energy Analysers
  • Concentration&Density Analysers
  • Fusion Analytical Systems Ltd

    address:BuildingA,Science&Technology Park,Zhangjiagang Free Trade Zone,Suzhou City,Jiangsu Province

    phone:+441315070216

    mailbox:9128889@qq.com