Flexim FLUXUS G721 CA Compressed Air Flow Meter (Obsolete)
Release time:2025-10-15 10:50:31 publisher:小编 Page View:

Flexim FLUXUS G721 CA Compressed Air Flow Meter (Obsolete)
This product is obsolete. Relevant documents and drawings are listed below. Please contact your local Emerson representative for your measurement needs.
- Fluid type
- Air, nitrogen, oxygen, helium, argon
- Accuracy
- Measurement uncertainty of the measuring system (volumetric flow rate): ±0.3 % of reading ±0,005 m/s (±0.02 ft/s)
Measurement uncertainty at the measuring point (volumetric flow rate): ±1…2 % of reading ±0,005 m/s (±0.02 ft/s)
- Repeatability
- 0.15 % of reading ±0,005 m/s (±0.02 ft/s)
- Range
- Flow Velocity Range: 0,01…35 m/s (0.03 to 115 ft/s), depending on pipe diameter
- Certifications/Approvals
- FM Class I /Div 2
ATEX/IECEx Zone 2
PESO
KOSHA
- Power supply
- 100-230VAC
24VDC
12VDC
- Pipe size
- 10 to 250 mm (0.39 to 9.8 inch)
- Pressure range
- 1barg (15 psig) to unlimited
- Temperature range (media)
- -40 to +130°C (-40 to +266°F)
- Output
- 4-20mA active/passive
4-20mA HART active/passive
pulse/frequency/binary
voltage
- Input
- Temperature
4-20mA active/passive
binary
voltage
- Communication Protocol
- Modbus RTU/TCP
BACnet MSTP/IP
Profibus PA
Foundation Fieldbus
- System configuration and installation
- For more detailed Information please download the Technical Specifications
Features
- Non-intrusive compressed air and technical gas flow measurement from 3 bar absolute onwards.
- Available as a dual channel meter, stainless steel housing, ATEX/IECEx and FM approval.
- Integrated standard volume flow calculation.
- Extreme measurement dynamics from lowest to highest flow velocities - easy detection of leakages and load peaks.
- Bi-directional measurement, able to detect back-flow
- Simple and cost-effective retrofitting without shut down.
- USB and LAN interface.
- Communication interfaces Modbus TCP, Modbus RTU, BACnet MS/TP, BACnet IP, M-Bus.
- Advanced Meter Verification.