FS2969 Water Vapour Transmitter
In-situ Water Vapour Analysis in High Humidity Applications
Moisture measurement improves product quality and consistency and reduces fuel costs for drying and baking processes.
Fissnel has enhanced its range of analysers by adding the FS2969 Water Vapour Transmitter and the FS2465HWV High Water Vapour Oxygen Probe

The FS2969 transmitter uses the measure of oxygen to calculate the level of water vapour by using the difference between the wet oxygen reading and the dry oxygen reading.
The Fissnel zirconia probes incorporate rugged zirconia sensors. Now there is a Fissnel oxygen probe designed especially for baking and drying ovens.
Used with the FS2969 water vapour transmitter, the FS2465HWV oxygen probe is capable of reading the oxygen concentration in atmospheres with up to 99.99% water vapour and at temperatures up to 600°C (1,100°F).
The FS2969 / FS2465HWV water vapour analysis provides rapid payback for processes such as:
•Drying ovens
•Baking ovens
•Paper drying hoods
•Gypsum and plasterboard dryers
•Timber drying kilns
The FS2969 / FS2465HWV water vapour analysis can provide accurate moisture control in atmospheres up to 600°C
Easy to operate, reliable and no regular calibration needed. Select the unit of measure to display and output from:
•Water Vapour %
•Dew Point
•Mixing Ratio
•Specific Humidity
•Relative Humidity
•Absolute Humidity
•Oxygen
Fast, Accurate and Reliable
The oxygen sensor, which measures water vapour due to oxygen displacement in the oven atmosphere, provides accurate and virtually drift-free measurement for years.
Highly responsive, eg: typically 3 seconds for indirect heated applications.
Controlling humidity
The FS2969 / FS2465HWV can be used with controllers, including PLC’s, to provide accurate continuous control of the moisture level.
Direct Fired Processes
The FS2969 / FS2465HWV measures the “wet” oxygen level of the process using an in situ zirconia oxygen probe and can accept a remote signal input (4-20mA) proportional to the dry oxygen level to then calculate the percent water vapour in the process. If this signal is not available from an existing CEMS installation then the FS2969 can be supplied with a reference gas sensor as a simple sampling system to determine the “dry” oxygen level in the process.
The probe can be inserted directly into the oven / dryer therefore eliminating the need for a high-maintenance sampling system.
Specifications – FS2969 Transmitter
Inputs
•Two zirconia oxygen probes or sensors or
•One zirconia sensor & auxiliary thermocouple type J, K, R or S
•Burner “On” signal (dry contact)
•Purge air flow switch
Outputs
•Four programmable alarm relays
•Two isolated 4-20mA or 0-20mA
•SSR outputs to purge & calibration check gas solenoid valves
Range of Outputs
•Water Vapour %:0 to 100%
•Dew Point: -50 to 100℃
•Mixing Ratio:0 to 10,000 g/Kg
•Specific Humidity:0 to 1,000 g/Kg
•Dryer Temperature:0 to 400℃
•Relative Humidity:0 to 100%
•Absolute Humidity:0 to 1,000 g/m³
•Oxygen:0 to 25%
Alarms
•Common alarm relay with 20 user selectable instrument alarm functions
•Three programmable process alarm relays
▫ Water Vapour Low/High
▫ Dew Point Low/High
▫ Mixing Ratio Low/High
▫ Specific Humidity Low/High
▫ Oxygen Low/High
▫ Probe Temperature Low
▫ Purge in Progress
▫ Cal Check in Progress
▫ Any alarm condition not selected for the common alarm
•Four separate alarm thresholds can be set for calculated process variables
•Multiple selections can be made for all relays
Alarm Contacts
•Normally open failsafe (open for alarm state)
•240VAC / 30VDC, 2A
Range of Local Indication
•Water Vapour %0 to 100%
•Dew Point-50 to 100℃
•Oxygen0 to 100%
•Mixing Ratio0 to 10,000g/Kg
•Specific Humidity0 to 1,000g/Kg
Network Interface
•RS-485 MODBUS™
Secondary Parameter Display
•Probe Thermocouple Temperature
•Probe EMF
•Probe Impedance
•Probe Oxygen %
•Zone 1 & 2 Water Vapour %
•Zone 1 & 2 Dew Point
•Zone 1 & 2 Mixing Ratio
•Zone 1 & 2 Specific Humidity
•Dryer Temperature
•Relative Humidity
•Absolute Humidity
•Ambient Temperature
•RGS Temperature
•Ambient RH%
•External Dry Oxygen
•Runtime
•Service Date
•4-20mA Output 1
•4-20mA Output 2
Options available will vary depending on device configuration
Accuracy
•±1% of the actual oxygen reading with a repeatability of 0.5%. For example, at 2% oxygen the accuracy would be±0.02% oxygen.
•Contact Fissnel for specific applications for other measured process variables
Environmental Rating
•Operating Temperature -25°C to 55°C
•Relative Humidity 5% to 95% (non-condensing)
•Altitude 2000m Maximum
Power Requirements
•Mains Voltage 100 to 240VAC -6/+10%, 50/60Hz
•Overvoltage Category II (IEC60364-4-443)
•Requires 5W for controller plus probe power
Degree of Protection
•IP65
•IP54 with internal reference air pump
Specifications – FS2465HWV Probe
Model | FS2465HWV |
Applications | High moisture atmospheres up to 600°C |
Probe Insertion Length | 250, 350, 500, 750, 1000mm |
Process Connection | 1.5″ BSPT or NPT |
Outer Sheath | 32mm OD 316 Stainless Steel with 42mm filter |
Electrical Connection | Supplied with weatherproof connector and cable specified length up to 50m |
Heater | Yes |
Internal Thermocouple | Type ‘K’ |
Response Time | Typically <4 seconds |
Head Temperature | 100°C Max |
Reference Air Connection | 1/4” tube |
Gas flow | <50cc/min |
Particulate Filter | 30µm sintered titanium alloy |
Weight | 2.1Kg + 160g per 100mm insertion length |