Welcome to the company website
hotline:+441315070216

Flexim FLUXUS F721 TE - Heat and Cold Metering in any Environment (Obsolete) TALK TO AN EXPERT

Release time:2025-10-16 10:22:48      publisher:小编  Page View:

Flexim-FLUXUS F721TE Heat and Cold Metering in any Environment.jpg

Flexim FLUXUS F721 TE - Heat and Cold Metering in any Environment (Obsolete)

Product Description

This product is obsolete. Relevant documents and drawings are listed below. Please contact your local Emerson representative for your measurement needs

Specifications

  • Fluid type
  • Water, water-glycol, typical heat transfer fluids
  • Accuracy
  • Measurement uncertainty of the measuring system (volumetric flow rate): ±0.3 % of reading ±0,005 m/s (±0.02 ft/s)
    Measurement uncertainty at the measuring point (volumetric flow rate): ±1 % of reading ±0,005 m/s (±0.02 ft/s)
  • Repeatability
  • 0.15 % of reading ±0,005 m/s (±0.02 ft/s)
  • Flow Channels
  • up to 2
  • Range
  • Flow Velocity Range: 0,01…25 m/s (0.03 to 82 ft/s), depending on pipe diameter
  • Certifications/Approvals
  • FM Class I /Div 2
    ATEX/IECEx Zone 2
    PESO
    KOSHA
  • Power supply
  • 100-230VAC
    24VDC
    12VDC
  • Pipe size
  • 10 to 2400 mm (0.39 to 94.5 inch)
  • Pressure range
  • -
  • Temperature range (media)
  • -40 to +240°C (-40 to +464°F)
  • Output
  • 4-20mA active/passive
    4-20mA HART active/passive
    pulse/frequency/binary
    voltage
  • Input
  • Temperature
  • Communication Protocol
  • Modbus RTU/TCP
    BACnet MSTP/IP
    Profibus PA
    Foundation Fieldbus
  • System configuration and installation
  • For more detailed Information please download the Technical Specifications

Features

  • Virtually unlimited application range - even at extreme temperatures from -200 up to +630 °C (-328 up to +1166 °F).
  • Integrated thermal energy calculation.
  • Highly accurate flow measurement with paired and traceable calibrated ultrasonic transducers.
  • Highly accurate temperature measurement with paired and traceable calibrated temperature sensors (according to DIN EN 1434-1).
  • Extremely high measuring dynamics from the lowest to the highest flow velocities - captures even the slightest flows at nighttime.
  • Simple, cost-effective retrofitting without any disruption to supply.
  • Tamper-proof storage of measuring data.
  • Advanced Meter Verification.


Previous article:No more
Next article:No more

CLASSIFICATION

  • Gas Analysers
  • Oxygen Probes
  • Moisture analyzer
  • Chromatographic analyzer
  • Tunnel sensor
  • Ultraviolet analyzer
  • Liquids Analysers
  • Steam Analysers
  • Compressed Air Analysers
  • Mass Flow Analysers
  • Thermal Energy Analysers
  • Concentration&Density Analysers
  • Fusion Analytical Systems Ltd

    address:BuildingA,Science&Technology Park,Zhangjiagang Free Trade Zone,Suzhou City,Jiangsu Province

    phone:+441315070216

    mailbox:9128889@qq.com